Carbon Monoxide Detection Tubes 0.3%/b (0.3 - 7 Vol%)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapours can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Carbon Monoxide Detection Tubes 0.3%/b (0.3 - 7 Vol%)
Standard Measuring Range: |
0.3 to 7 Vol. % CO |
Number of Strokes (n): |
1 |
Time for Measurement: |
approx. 30 sec. |
Standard Deviation: |
±10 to 15 % |
Color Change: |
white ?> brown green |
Temperature: |
0 to 50° C |
Absolute Humidity: |
max. 50 mg H2O / L |
Reaction Principle: |
5 CO + I2O5 ??H2S2O7??> I2 + 5 CO2 |
Cross Sensitivity: |
The following do not influence the display of 0.3 vol. % CO:
- 10000 ppm n-octane
- 300 ppm benzene
- 500 ppm hydrogen sulphide
- 500 ppm sulphur dioxide
- 500 ppm nitrogen dioxide
- 300 ppm butadiene
- 250 ppm chloroform
- 3000 ppm acetylene result in a display of 0.3 vol. %
|
Carbon Monoxide Detection Tubes 0.3%/b (0.3 - 7 Vol%)
There are no reviews yet.