Chlorobenzene Detection Tubes 5/a (5 - 200 ppm)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Chlorobenzene Detection Tubes 5/a (5 - 200 ppm)
Standard Measuring Range: |
5 to 200 ppm |
Number of Strokes (n): |
10 |
Time for Measurement: |
approx. 3 min |
Standard Deviation: |
±10 to 15 % |
Color Change: |
blue ?> yellowish-gray |
Temperature: |
10 to 40° C |
Absolute Humidity: |
3 to 15 mg H2O / L |
Reaction Principle: |
a) C6H5Cl + CrVI ??> HCl b) HCl + bromophenol blue ??> yellow reaction product |
Cross Sensitivity |
Other chlorinated hydrocarbons are indicated as well, but with different sensitivities. Methylene chloride does not affect the indication. Chlorine and hydrogen chloride in the TLV range are absorbed in the pre-layer, but in such concentrations do not affect the indication. |
Chlorobenzene Detection Tubes 5/a (5 - 200 ppm)
There are no reviews yet.