Hydrogen Detection Tubes 0.2%/a (0.2 - 2 Vol.%)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Hydrogen Detection Tubes 0.2%/a (0.2 - 2 Vol.%)
Standard Measuring Range: |
0.2 to 2.0 Vol. % |
Number of Strokes (n): |
1 |
Time for Measurement: |
approx. 1 min |
Standard Deviation: |
±15 to 20 % |
Color Change: |
green yellow ?> turquoise blue |
Temperature: |
20 to 40° C |
Absolute Humidity: |
max. 50 mg H2O / L |
Reaction Principle: |
a) H2 + 1/2 O2 ??> H2O
b) H2O + Indicator ??> turquoise blue reaction product |
Cross Sensitivity: |
No interference by: 0.1 Vol. % acetylene 6 Vol. % alcohol 6 Vol. % ammonia 0.5 Vol. % carbon monoxide |
Additional Information: |
The indicating layer is heated up by hydrogen concentrations of more than 10 vol. %. The air sample must not contain additional flammable substances whose ignition temperature is below 250 °C/ 482 F as this will cause an explosion risk. |
Hydrogen Detection Tubes 0.2%/a (0.2 - 2 Vol.%)
There are no reviews yet.