Hydrogen Sulfide Detection Tubes 2%/a (2 - 40% vol.)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Hydrogen Sulfide Detection Tubes 2%/a (2 - 40% vol.)
Standard Measuring Range: |
2 to 40 Vol. % |
Number of strokes n: |
1 |
Time for Measurement: |
approx. 1 min |
Standard Deviation: |
± 5 to 10 % |
Color Change: |
pale blue ??> black |
Temperature: |
0 to 40°C |
Absolute Humidity: |
3 to 20 mg H2O / L |
Reaction Principle: |
H2S + Cu2+ ??> CuS+ 2 H+ |
Cross Sensitivity: |
No interference by:
5,000 ppm sulfur dioxide 1,000 ppm hydrochloric acid 1,000 ppm ethyl mercaptan |
Hydrogen Sulfide Detection Tubes 2%/a (2 - 40% vol.)
There are no reviews yet.