Methyl Acrylate Detection Tubes 5/a (5 - 200 ppm)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Methyl Acrylate Detection Tubes 5/a (5 - 200 ppm)
Standard Measuring Range: |
5 to 200 ppm |
Number of strokes n: |
20 |
Time for Measurement: |
approx. 5 min |
Standard Deviation: |
30 to 40 % |
Color Change: |
yellow ??> blue |
Temperature: |
15 to 35°C |
Absolute Humidity: |
5 to 12 mg H2O / L |
Reaction Principle: |
CH2=CH-COOCH3 + Pd-Molybdate complex ??> blue reaction product |
Cross Sensitivity: |
Other compounds with C=C double bonds are indicated, but with different sensitivities. It is impossible to differentiate between them. It is impossible to measure methyl acrylate in the presence of hydrogen sulfide. Hydrogen sulfide will discolor the indicating layer black. Carbon monoxide in high concentrations discolors the indicating layer pale blue grey. |
Methyl Acrylate Detection Tubes 5/a (5 - 200 ppm)