Thioether Detection Tubes (1 mg/m3)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Thioether Detection Tubes (1 mg/m3)
Standard Measuring Range: |
1 mg/m3 is the minimum detectable concentration in the form of a ring. |
Number of strokes n: |
8 |
Time for Measurement: |
approx. 1.5 min |
Standard Deviation: |
± 50 % |
Color Change: |
yellow ??> orange |
Temperature: |
0 to 40 °C |
Absolute Humidity: |
< 50 mg H2O / L |
Reaction Principle: |
R'-S-R + AuCl3 + Chloramide ??> orange reaction product |
Cross Sensitivity: |
Various thioethers are indicated, but it is impossible to differentiate between them. |
Additional Information: |
After performing the required eight pump strokes the reagent ampoule must be broken and the liquid transferred completely onto the indication layer. |
Thioether Detection Tubes (1 mg/m3)
There are no reviews yet.