Vinyl Chloride Detection Tubes 100/a (100 - 3000 ppm)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Vinyl Chloride Detection Tubes 100/a (100 - 3000 ppm)
Standard Measuring Range: |
100 to 3,000 ppm |
Number of Strokes (n): |
18 to 1 |
Time for Measurement: |
max. 3 min |
Standard Deviation: |
± 30 % |
Color Change: |
violet ??> light brown |
Temperature: |
0 to 40° C |
Absolute Humidity: |
< 30 mg H2O / L |
Reaction Principle: |
CH2=CHCl + MnO4- ??> MnIV + various oxidation products |
Cross Sensitivity: |
Many organic compounds with C=C double bonds are indicated, but with different sensitivities. It is impossible to differentiate between them. It is impossible to measure vinyl chloride in the presence of dialkyl sulfide. |
Vinyl Chloride Detection Tubes 100/a (100 - 3000 ppm)
There are no reviews yet.