Phosphine Detection Tubes 0.1/b (in acetylene) (0.1 - 15 ppm)
For short-term measurements more than 160 Draeger-Tubes are available to measure the spot concentrations of specific gases. Measurement usually takes between 4 seconds and 15 minutes. The tubes are used either manually with the Draeger-Tube Accuro Pump or automatically with the Draeger X-act 5000.
A wide range of different gases and vapors can be detected and measured, such as:
- Determining and measuring concentration peaks
- Measuring personal exposure in the inhalation area
- Detecting leaks in pipelines, gas installations etc.
- Air analysis in sewers, shafts and confined spaces
Phosphine Detection Tubes 0.1/b (in acetylene) (0.1 - 15 ppm)
Standard Measuring Range: |
0.1 to 1.0 ppm / 1 to 15 ppm |
Number of strokes n: |
10 / 1 |
Time for Measurement: |
approx. 4 min / approx. 20 sec |
Standard Deviation: |
± 15 to 20 % |
Color Change: |
yellow orange ??> red violet |
Temperature: |
2 to 40 °C |
Absolute Humidity: |
< 20 mg / L |
Reaction Principle: |
PH3 + HgCl2 ??> Hg-Phosphide + HCl HCl + pH-Indicator ??> red violet reaction product |
Cross Sensitivity: |
Arsine and Hydrogen Sulfide will be indicated with differing sensitivities. |