Acetic Acid Detection Tube (0.125 to 25 ppm)
Measures Acetic Acid with a range of 0.125 to 25 ppm. Other substances measurable with this detection tube are listed below.
- Measuring Range:
- 0.125 to .25 ppm - 2 pump strokes
- 0.25 to 10 ppm - 1 pump stroke
- 10 to 25 ppm - 1/2 pump stroke
- Number of pumps: 2, 1, 1/2
- Sampling Time: 1.5 minutes per pump stroke
- Changes from Pink to Pale Yellow
- 2 Year Shelf Life (in the refrigerator)
- Reaction principle: CH3CO2H + Base → Reaction product
- Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
Other substances measurable with this detector tube
Substance |
Correction |
No. of Pump Strokes |
Measuring Range |
Acetic anhydride |
Factor: 0.6 |
1 |
0.15 to 6 ppm |
Acrylic acid |
Factor: 1.8 |
1 |
0.45 to 18 ppm |
Butyric Acid |
Factor: 1.3 |
1 |
0.325 to 13 ppm |
Formic acid |
Factor: 2.0 |
1 |
0.5 to 20 ppm |
Isovaleric acid |
Factor: 1.5 |
1 |
0.38 to 15 ppm |
Methacrylic |
Factor: 1.4 |
1 |
0.35 to 14 ppm |
Propionic acid |
Factor: 1.0 |
1 |
0.25 to 10 ppm |
Valeric acid |
Factor: 1.5 |
1 |
0.38 to 15 ppm |
Acetic Acid Detection Tube (0.125 to 25 ppm)
There are no reviews yet.