Nitro Compounds/Nitroethan Detection Tubes (0.5 to 30 ppm)
Measures Nitro Compounds (Nitroparaffin) (Pyrotec)
Performance:
Measuring Range: |
0.5 to 30 ppm |
Number of Pump Strokes: |
1 (100 ml) |
Correction Factor: |
1 |
Sampling Time: |
2 min |
Detecting Limit: |
0.1 ppm (1 Pump Stroke) |
Color Change: |
White to Yellowish Orange |
Corrections for temperature & humidity |
Unnecessary |
Shelf Life: |
3 Years |
Reaction Principle:
- Pyrotec: Nitro compounds → NOx
- Pyrotube: NOx + CrO3 + H2SO4 → NO2
- NO2 + o-Tolidine → Yellowish orange product
Possible coexisting substances and their interferences:
Substance |
Concentration |
Interference |
Changes color by itself to |
Chlorine dioxide |
|
+ |
Yellowish orange |
Halogens |
|
+ |
Yellowish orange |
Halogenated hydrocarbons |
|
+ |
Yellowish orange |
Hydrogen chloride |
|
+ |
Yellowish orange |
Sulfur dioxide |
≧ 25 ppm |
- (Bleaching) |
No |
Hydrogen sulfide |
≧ 25 ppm |
- (Bleaching) |
No |
Substances measurable with this Pyrotube:
Substances |
n |
Correction Factor |
Measuring Range |
Acetonitrile |
1 |
6.0 |
3 to 180 ppm |
Nitroethane |
1 |
8.0 |
4 to 240 ppm |
Nitrogen dioxide |
1 |
1.0 |
0.5 to 30 ppm |
Nitromethane |
1 |
10.0 |
5 to 300 ppm |
1-Nitropropane |
1 |
8.4 |
4.2 to 252 ppm |
2-Nitropropane |
1 |
7.4 |
3.7 to 222 ppm |
Nitro Compounds/Nitroethan Detection Tubes (0.5 to 30 ppm)
There are no reviews yet.