Acrylonitrile Detection Tubes (0.1 to 18 ppm)
This detector tube measures Acrylonitrile within 0.1 to 18.0 ppm.
- Measuring Range:
- 0.1 to 0.2 ppm - 4 pump strokes - Correction Factor: 1/2
- 0.2 to 6.0 ppm - 2 pump strokes - Correction Factor: 1
- 6.0 to 18.0 ppm - 1 pump stroke - Correction Factor: 3
- Sampling Time: 2 minutes per pump stroke
- Detecting limit: 0.05 ppm (4 pump strokes)
- Changes from Yellow to Pink
- Corrections for temperature & humidity: Unnecessary
- Relative Standard Deviation: 10 %(for 0.2 to 2.0 ppm), 5 %(for 2.0 to 6.0 ppm)
- 3 Year Shelf Life
- Reaction Principle:
- CH2:CHCN + Cr6+ + H2SO4 → HCN
- 2HCN + HgCl2 → 2HCl
- HCl + Base → Chloride
- Store the tubes at a cool and dark place
Possible coexisting substances and their interferences
Substance |
Concentration |
Interference |
Changes color by itself to |
Acetone cyanohydrin |
|
+ |
Pink |
Nitriles (≧ C3) |
|
+ |
Pink |
Alcohols, Esters, Ketones |
|
No |
No |
Aromatic hydrocarbons |
|
No |
No |
Hydrogen chloride |
|
No |
No |
Hydrogen cyanide |
|
No |
No |
Other substances measurable with this detector tube:
Substances |
Correction Factor |
No. of Pump Strokes |
Measuring Range |
Butyronitrile |
30 |
1 |
6 to 180 ppm |
2-Methyl-3-butenenitrile |
2.0 |
2 |
0.4 to 12.0 ppm |
2-Pentenenitrile |
1.2 |
2 |
0.24 to 7.2 ppm |
3-Pentenenitrile |
2.0 |
2 |
0.4 to 12.0 ppm |
Acrylonitrile Detection Tubes (0.1 to 18 ppm)
There are no reviews yet.