Hexane Detection Tubes (4 to 1200 ppm)
Gastec Detector Tube No 102L is used for the detection of Hexane in the air of industrial areas and in environmental atmospheric conditions within the measuring range of 4-1200 ppm.
- Measuring Range: 4 to 50 ppm, 50 to 1200 ppm
- Number of pump strokes: 5, 1
- Correction Factor: 1/12, 1
- Sampling Time: 1.5 minutes per pump stroke
- Changes from Yellowish brown to Greenish brown
- Corrections for temperature & humidity: Unnecessary
- Reaction Principle: CH3(CH2)4CH3 + CR6+ + H2SO4 → Cr3+
- Relative Standard Deviation: 10% (for 50 to 400 ppm), 5% (for 400 to 1200 ppm)
- 3 Year Shelf Life
- Store the tubes at cool and dark place
Possible coexisting substances and their interferences:
Substance |
Concentration |
Interference |
Changes color by itself to |
Acetylene |
|
+ |
Blackish brown |
Aromatic hydrocarbons |
|
+ |
Greenish brown |
Alcohols, Esters, Ketones |
|
+ |
Greenish brown |
Organic solvents (≧ C3) |
|
+ |
Greenish brown |
Hydrogen sulfide |
|
+ |
Blackish brown |
Sulfur dioxide |
|
+ |
Greenish brown |
Other substances measurable with this detector tube:
Substance:
|
Correction Factor:
|
No. of Pump Strokes:
|
Measuring Range:
|
Acrylonitrile
|
Factor: 12
|
1
|
0.06 to 1.14%
|
Tert-Butyl Alcohol
|
Factor: 10
|
2
|
0.05 to 1.2%
|
Chlorocyclohexane
|
Factor: 1
|
2
|
50 to 1200ppm
|
Cyclohexane
|
Factor: 1.2
|
1
|
60 to 1440 ppm
|
Hexane Detection Tubes (4 to 1200 ppm)
There are no reviews yet.