Arsine Detection Tubes (0.04 to 10 ppm)
This detector tube measures Arsinewithin a range of 0.04 to 10 ppm
- Measuring Range:
- 0.04 to 0.1 ppm - 10 pump strokes
Correction Factor: 0.4
- 0.1 to 1.5 ppm - 5 pump strokes
Correction Factor: 1
- 1.5 to 2.4 ppm - 3 pump strokes
Correction Factor: 1.6
- 2.4 to 10 ppm - 1 pump stroke
Correction Factor: 6.7
- Sampling Time: 1.5 minutes per pump stroke
- Detecting Limit: 0.02 ppm (10 pump strokes)
- Changes from Yellow to Red
- Corrections for temperature & humidity: Unnecessary
- Relative Standard Deviation:10% (for 0.1 to 0.5 ppm), 5% (for 0.5 to 1.5 ppm)
- 2 Year Shelf Life
- Reaction Principle:
- AsH3 + 3HgCl2 → As(HgCl)3 + 3HCl
- HCl + Base → Chloride
- Store the tubes at a cool and dark place.
Possible coexisting substances and their interferences:
Substance |
Concentration |
Interference |
Changes color by itself to |
Phosphine |
≧ 1/10 |
+ |
Red |
Diborane |
|
No |
No |
Hydrogen chloride |
|
No |
No |
Arsine Detection Tubes (0.04 to 10 ppm)
There are no reviews yet.