Hydrogen Cyanide (HCN) Detection Tubes (0.05 to 1.6%)
Gastec Detection Tube No. 12H measures Hydrogen Cyanide with a Range of 0.05 to 1.6%.
- Measuring Range: 0.05 to 1.6%
- Number of Pump Strokes: 1 (100 ml)
- Correction Factor: 1
- Sampling Time: 1 minute per pump stroke
- Detecting Limit: 0.005% (1 pump stroke)
- Changes from Yellow to White
- Corrections for temperature & humidity: Temperature correction is necessary
- Reaction Principle: HCN + Na2Pd(SO3)2 → Reaction product
- Relative Standard Deviation: 10% (for 0.05 to 0.4 %), 5% (for 0.4 to 1.6 %)
- 3 Year Shelf Life
- Store the tubes at cool and dark place.
Possible coexisting substances and their interferences
Substance |
Interference |
Changes color by itself to |
Carbon monoxide |
+ |
Blackish brown |
Ethylene |
+ |
Blackish brown |
Hydrogen sulfide |
+ |
Blackish brown |
Hydrogen Cyanide (HCN) Detection Tubes (0.05 to 1.6%)