Hydrogen Sulfide (H2S) Detection Tubes (25 to 1600 ppm)
Gastec Detection Tube No. 4HM measures Hydrogen Sulfide with a Range of 25 to 1600 ppm.
- Measuring Range:
- 25 to 50 ppm
- 50 to 800 ppm
- 080 to 1600 ppm
- Number of Pump Strokes: 2, 1, 1/2
- Correction Factor: 1/2, 1, 2
- Sampling Time: 45 seconds per pump stroke
- Detecting Limit: 5 ppm (2 pump strokes)
- Changes from White to Brown
- Corrections for temperature & humidity: Unnecessary
- Reaction Principle: H2S + Pb(CH3COO)2 → PbS + 2CH3COOH
- Relative Standard Deviation: 5% (for 50 to 800 ppm)
- 3 Year Shelf Life
- Store the tubes at cool and dark place
Possible coexisting substances and their interferences:
Substance |
Concentration |
Interference |
Changes color by itself to |
Nitrogen dioxide |
≧ 1/4 |
- |
No |
Sulfur dioxide |
≧ 1/1 |
+ |
No |
Ammonia |
|
No |
No |
Carbon dioxide |
|
No |
No |
Carbon monoxide |
|
No |
No |
Mercaptans |
|
No |
No |
Organic gases & vapors |
|
No |
No |
Hydrogen Sulfide (H2S) Detection Tubes (25 to 1600 ppm)
There are no reviews yet.