identiFINDER R200 Radiation Detector
The FLIR identiFINDER R200 is a rugged, pager-sized Spectroscopic Personal Radiation
Detector (SPRD) that provides full ANSI N42.32 Personal Radiation Detector (PRD) compliance
and features next-generation solid state detector read-out technology that delivers ANSI
N42.48 SPRD compliance with nuclide identification.
Law enforcement agencies and first
responders use the R200 during routine traffic stops or high visibility events and in mass
transit or critical infrastructure entry control points.
The OneTouch Reachback feature uses
the latest Bluetooth and web server technologies to provide large-scale
situational awareness by alerting others before arriving on-scene. The clear user interface
and simple data presentation common to all identiFINDER products allow the R200 to quickly
integrate with existing operational protocols and reduce the training burden.
Available as a standard unit or with ZnS detectors for neutron detection.
RADIOISOTOPE IDENTIFICATION
- ANSI N42.32 PRD compliant
- ANSI N42.48 SPRD compliant, with nuclide identification
- SiPM technology with CsI detectors provide <7.5% resolution
- Field-proven template matching algorithms
PAGER-SIZED & RUGGED
- 1.5 meter drop tested, IP67-rated
- No user maintenance
- Automatically calibrated and stabilized
SHARED COMMON USER INTERFACE
- Simple three-button interface
- Clear, easy-to-read results
- Web-based software for easy data retrieval
Replacement product is the FLIR R225
identiFINDER R200 Radiation Detector
SPECIFICATIONS:
- Technology: Spectroscopic personal radiation detector (SPRD)
- Gamma (CSL): (18mm)^3 CesiumIodide (CsI)with Silicon Photomultiplier (SiPM)
- Energy Range (Gamma): 25keV - 3MeV=
- Gamma Spectrum: 1024 channels; 3 MeV
- Dose Rate / Accuracy (Cs-137): ≤100 nSv/h – 250 µSv/h (≤10µRem/h – 25mRem/h); ±20%
- Typical Resolution: ≤7.5 % FWHM at 662 keV
- Service Interval: Recommended five year factory maintenance interval; annual dose rate calibration interval
SAMPLING & ANALYSIS:
- Sample Introduction: Absorption of EM gamma emissions
- Threats: Detects gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
- Compliance: ANSI N42.32 PRD standard fully compliant and ANSI N42.48 SPRD standard fully compliant,
including nuclide identification
- Sampling & Analysis: From a few seconds to minutes
SYSTEM INTERFACE:
- Display: Transflective Monochrome LCD
- Communication: USB 2.0; micro-AB socket; integrated Bluetooth® up to 10m range
- Data Storage: 30MB internalmemory; up to 5000 spectra
- Training Requirements: <10mins for operator; 1 day for advanced user
- Software: On-board webserver software
POWER
- Input Voltage: 100-240 VAC (wall and car adapters and USB cable supplied)
- Battery Specs: Internalsingle cell Li-ion: operational batterylife ≥36h; replaceable back-up CR-
123A: operational battery life ≥18h; Recharge
time ≤6h when using AC or USB power source
- Cold Start Time: <2 mins from cold start
ENVIRONMENTAL:
- Operating Temp: -4 to 122 °F (-20 to 50 °C)
- Operating Humidity: 93% RH @ 35 °C non-condensing
- Storage Temp: 14 to 95 °F (-10 to 35 °C)
- Enclosure & Protection: Plastic injection with rubber overmold; protection rating IP67 according to IEC 60529
PHYSICAL
- Dimensions: 5.7 x 2.2 x 1.9 in (14.5 x 5.6 x 4.8 cm
- Weight: ≤0.88 lb (0.4 kg)
identiFINDER R200 Radiation Detector