G7 Replacement Sensor Cartridge

There are no reviews yet. | Write a review
Item #: J-
Min Order: 0
Order Qty: Must order in multiples of 1
Quote Required
Phantom Variant:
Sensor 1:
Sensor 2:
Sensor 3:
Sensor 4:
Pump Selection:
Price Offset:
Update price
View additional buying options
Product Details

G7 Replacement Sensor Cartridge

The G7 line can be configured for up to five different gases. These devices use a replaceable sensor cartidge that is available as either pumped or diffusion. Sensor cartridges can easily be replaced in the field, with each cartridge holding its own bump and calibration data.

Connectivity

G7 devices constantly stream situational data to the Blackline Live safety platform. The safety status of every team member is visible at a glance, and should something happen, this data can help identify precisely where to send help and how to prepare first responders for the scene.

G7 Replacement Sensor Cartridge

Gas Sensor type Range Resolution
Ammonia (NH3) Electrochemical 0–100 ppm 0.1 ppm
High-range ammonia (NH3) Electrochemical 0–500 ppm 1 ppm
Carbon monoxide (CO) Electrochemical 0–500 ppm 1 ppm
High-range carbon monoxide (CO) Electrochemical 0–2000 ppm 5 ppm
Hydrogen resistant carbon monoxide (CO-H) Electrochemical 0–500 ppm 1 ppm
Carbon dioxide (CO2) NDIR 0–50,000 ppm 50 ppm
Chlorine (Cl2) Electrochemical 0–20 ppm 0.1 ppm
Chlorine dioxide (ClO2) Electrochemical 0–2 ppm 0.01 ppm
COSH Electrochemical 0–500 ppm CO,
0–100 ppm H2S
1 ppm CO, 0.1 ppm H2S
Hydrogen cyanide (HCN) Electrochemical 0–30 ppm 0.1 ppm
Hydrogen sulfide (H2S) Electrochemical 0–100 ppm 0.1 ppm
High-range hydrogen sulfide (H2S) Electrochemical 0-500 ppm 0.5 ppm
LEL-MPS
See Blackline's LEL-MPS datasheet for more information
Molecular property spectrometerTM 0–100% LEL 0.1% LEL
LEL-infrared (LEL-IR) NDIR 0–100% LEL 1% LEL
Nitrogen dioxide (NO2) Electrochemical 0–50 ppm 0.1 ppm
Oxygen (O2) Pumped electrochemical 0–25% vol 0.1% vol
Ozone (O ) Electrochemical 0–1 ppm 0.01 ppm
Photoionization (PID) ppm PID 0–4,000 ppm* Dynamic resolution*,
0.1 ppm
Sulfur dioxide (SO2) Electrochemical 0–100 ppm 0.1 ppm