Trichloroethylene Detection Tubes (1-70 ppm)
Measures Trichloroethylene With a Range of 1-70 ppm. Other substance measurable with this detector tube is Benzyl Chloride.
- Measuring Range:
- 1 to 2 ppm
- 2 to 25 ppm
- 25 to 70 ppm
- Number of Pump Strokes: 2, 1, 1/2
- Correction Factor: 1/2, 1, 2.8
- Sampling Time: 45 seconds per pump stroke
- Detecting Limit: 0.4 ppm (n=2)
- Changes from Yellow to Purple
- Reaction Principle:
- Cl2>C:CHCl + PbO2> + H2>SO4> → HCl
HCl + Basic Compound → Chloride
- Coefficient of Variation: 10% (for 1 to 5 ppm), 5% (for 5 to 25 ppm)
- 2 Year Shelf Life
- TLV-TWA, C (ACGIH) (ppm): 10
- Store the tubes in the refrigerator to keep at 10ºC (50ºF) or below.
- Comes in a Box of 10
Other substance measurable with this detector tube:
Substance:
|
Correction Factor:
|
No of Pump Strokes:
|
Measuring Range:
|
Benzyl chloride
|
0.8
|
2
|
1.6 to 20 ppm
|
Trichloroethylene Detection Tubes (1-70 ppm)