Pen Radiation Dosimeter

There are no reviews yet. | Write a review
Item #: PEN
Min Order: 0
Order Qty: Must order in multiples of 1
$165.00
Type:
Update price
View additional buying options
Product Details

Pen Radiation Dosimeter

Pen Dosimeters

The advanced PEN direct reading dosimeters are rugged, precision instruments. They are higher quality and have greater reliability than other dosimeters of this type.

They measure and directly read, at any time, accumulated dose (quantity of gamma and x-ray exposure). PEN dosimeters are designed to satisfy military specifications for the RADIAC METER IM-264/PD and ANSI N 13.5 and N322 requirements. A sturdy metal clip attaches the dosimeter to a pocket or any object to monitor total radiation exposure. They are hermetically sealed and immersion proof.

The Pen Dosimeter requires The Charger for calibration. (Sold separately)

Specifications

Exposure Range (gamma and x-rays)

PEN200mR Scale increments of 10mR
PEN500mR Scale increments of 20mR
PEN2R increments of 100 mR
PEN5R
increments of 200 mR
PEN20R increments of 1R
PEN2mSv increments of .1mSv
PEN5mSv

increments of .2mSv

Electrical Leakage:In the absence of radiation, the dosimeters leakage or self discharge is less than 0.5% of full scale in 24 hours at 50° C. At 20°C dosimeters will read background radiation. After gross over exposure totaling up to 2000 R the leakage is less than 5% of full scale in 48 hours at 20°C. Thereafter, the leakage will decrease to original values.

Charging Voltage:Dosimeters are capable of being charged to "zero" with 140 to 195 volts.

Operational Characteristics:A maximum change in sensitivity of ±10% may occur under any probable combination of the following:

  • Temperature range below -20°C (-4°F) or above +50°C (122°F)
  • Greater than 50,000 foot altitude for one month
  • Relative humidity greater than 95% Highly resistant to shock and vibration

Pen Radiation Dosimeter

Energy Dependence ±10% maximum change in sensitivity for x and
gamma ray energies from 16 keV to 8 MeV.
Charging Voltage Dosimeters are capable of being charged to "zero"
with 140 to 195 volts.
Accuracy ±10% of true dose for Cs-137 or Co-60 gamma.
Rate Response Dosimeters are dose rate independent.
Enclosure Material Barrel - carbon fiber - filled, high-strength,
electrically-conducting plastic with metal clip.
Weight Approx. 19 grams (0.7 oz)
Size PEN - 200, 500
2mSv, 5mSv Length: 11 cm (4.48 in.)
Diameter: 1.5 cm (0.6 in.)
PEN - 2, 5, 20 Length: 11.5 cm (4.52 in.)
Diameter: 1.5 cm (0.6 in.)
Options Protective sapphire lens
Warranty 2 year limited warranty

Pen Radiation Dosimeter

There are no reviews yet.


Related Items
Radiation Alert Pen Dosimeter Charger from S.E. International

$290.00
Monitor 4EC from S.E. International
Monitor 4EC

S.E. International


$475.00
Radiation Alert Monitor 4 Monitor 4
Radiation Alert Monitor 4

S.E. International


$445.00
Sentry EC from S.E. International
Sentry EC

S.E. International


$385.00