identiFINDER S900 Fixed Radiation Detector

There are no reviews yet. | Write a review
Item #: S900-
Min Order: 0
Order Qty: Must order in multiples of 1
Quote Required
Option:
Update price
Qty:
View additional buying options
Product Details

identiFINDER S900 Fixed Radiation Detector

The identiFINDER S900 is an autonomous sensor that delivers real-time radiation detection and identification. It detects the presence or movement of radioactive material across borders, into buildings, at large public gatherings, and events. It uses the same advanced template matching algorithms as the industry-leading identiFINDER R-series to separate innocent material, such as medical patients, from threatening sources – a unique feature not offered by other area monitors.

identiFINDER S900 units are available in a wide variety of form factors that can be tailored to application-specific environments and sensitivities. Deployment can begin with a standalone system and expand to include a network of systems as needs change. The detection units can be openly installed or concealed from view, allowing security personnel to interdict threats without alerting an individual it has been detected. It automatically calibrates and stabilizes without any user maintenance. The hassle-free operation and continuous data stream provided by identiFINDER S900 simplifies deployment and integration within existing security networks without disrupting daily activities.

RAPID, AUTONOMOUS MONITORING

Automatically analyzes collected data against extensive library when a change in background radiation is detected.

  • Radiation identification within seconds
  • Real-time situational awareness with continuous, rapid identification
  • Locates position of source or tracks progression
  • Autonomous operation frees security personnel for other vital security tasks

SCALABLE AND EXPANDABLE DEPLOYMENT ARCHITECTURE

Available in variety of sizes and housing and can be openly installed or concealed for high consequence threat interdiction.

  • Small form factor allows it to be concealed
  • Easily integrates into existing security architecture or city-wide networks
  • Interchangeable hardware minimizes downtime and simplifies deployment
  • No user maintenance

SEPARATE BENIGN SOURCES FROM TRUE THREATS

Separates innocent material, such as medical patients, from threatening sources - a unique feature not offered by other area monitors.

  • Simple alarm screens and data presentation
  • Analyzes, logs, and provides access to complex spectroscopic information
  • Uniform responses with accurate summation of data

identiFINDER S900 Fixed Radiation Detector

Technology: Autonomous radiation sensor
Product Variants: 203.2-NG(1), 203.2-NGH(2), 403.3-NG(3), 403.3-NGH(4), 416.1-NG(5), 416.1-NGH(6)
Gamma (Nal): 2.0 x 3.0in (51 x 76mm);
2.0 x 4.0 x 16.0in (51 x 102 x 406mm)(5,6)
Gamma (High Dose Rate): Energy compensated Geiger-Müller detector
Neutrons (He-3 PCT): 0.7 x 4.2in (19 x 106mm)(2,6);
0.75 x 3.0in (19.05 x 76.2mm)(4)
Energy Range (Gamma): 20 keV - 3 MeV
Throughput: >100 kcps
Max. Input Count Rate: 300 kcps
Dose Rate Range (1-4): 0.01 µµSv/h – 1 Sv/h (1.0 µrem/h – 100 rem/h)
Dose Rate Range (5-6): 0 µSv/h – 1 Sv/h (0 µrem/h – 100 rem/h)
Gamma Spectrum: Multiple payload ports, multiple accessories, sensors and disruptors supported
Controller: 1024 channels; 3 MeV
Dose Rate / Accuracy: 50 keV - 1500 keV; ±30 %
Scintillator Operating Range (1-4): 0 µSv/h – 100 Sv/h (0 rem/h – 10 mrem/h)
Scintillator Operating Range (5-6): 0 µSv/h – 20 Sv/h (0 rem/h – 2.0 mrem/h)
Geiger-Müller Operating Range (1-4): 100 µSv/h – 10 mSv/h (10 mrem/h – 1.0 rem/h)
Geiger-Müller Operating Range (5-6): 20 µSv/h – 10 mSv/h (2.0 mrem/h – 1.0 rem/h)
Overload Threshold: 10 mSv/h – 1 Sv/h (1.0 rem/h – 100 rem/h)
Neutron Sensitivity (2, 4, 6): 11 cps/nv; ±20 % thermal neutrons
Stabilization: K-40 calibration source and LED
Typical Resolution: ≤8 % FWHM at 662 keV
Service Interval: Recommended two-year service interval
Sampling & Analysis
Sample Introduction: Absorption of EM gamma or neutron emissions
Threats: Detects neutron or gamma radiation emitted from natural occurrences in the environment, special nuclear material, industrial, or medical material
Sampling & Analysis: From a few seconds to minutes
System Interface
Display & Alerts: identiFINDER S900 Data Protocol for network integration
Communication: Ethernet RJ45, 10 Mbit/s, 100 Mbit/s
Embedded Software: Windows CE operating system
Training Requirements: <10 mins for operator; 1/2 day for advanced user
Power
Input Voltage: DC 12V, 3W (1-6); Power over Ethernet (PoE) (1-6)
Cold Start Time: 15 mins from cold start
Environmental
Operating Temp: -4 to 122 °F (-20 to 50 °C)
Operating Humidity: 10 to 80%, non-condensing
Storage Temp: -22 to 158 °F (-30 to 70 °C)
Physical Features
Dimensions (HxDia.) / Weight (1-2): 25.8 x 2.5 in (654 x 63 mm) / 5.3 lb (2.4 kg)
Dimensions (HxDia.) / Weight (3-4): 29.1 x 5.5 in (740 x 140 mm) / 17.6 lb (8.0 kg)
Dimensions (HxWxD) / Weight (5-6): 35.9 x 8.6 x 6.8 in (911 x 218 x 173 mm) / 46.3 lb (21.0 kg)
Enclosure & Protection: Aluminium (1-2,5-6); PVC-U (3,4);




protection ratings IP54 (1-2), IP55 (3-4), IP62 (5-6)

identiFINDER S900 Fixed Radiation Detector

identiFINDER S900 DU 416.1-NGH For harsh environmental deployments. NaI(Tl) scintillation detector with K40 for calibration verification and DSP based electronic with LED stabilization. Wired gamma unit with 2" x 4" x 16" NaI detector, GM tube for high dose rate situations, and He-3 tube for neutron detection in a weatherproof aluminum housing.
identiFINDER S900 DU 416.1-NG Ruggized housing for harsh environmental deployments. Consists of an NaI(Tl) scintillation detector with K40 for calibration verification and a DSP based electronic with LED stabilization. Wired gamma unit only with 2" x 4" x 16" NaI detector and GM tube for high dose rate situations in weatherproof aluminum housing
identiFINDER S900 DU 403.3-NGH Ruggized housing for harsh environmental deployments. NaI(Tl) scintillation detector with K40 for calibration verification and DSP based electronic with LED stabilization. Wired gamma unit with 2" x 3" NaI detector, GM tube for high dose rate situations, and He-3 tube for neutron detection in a weatherproof PVC housing
identiFINDER S900 DU 203.2-NGH Encapsulated system suitable for installations on walls, inside door jams, behind counters, etc. Consists of 2" x 3" NaI(Tl) scintillation detector with K40 for calibration verification and DSP based dsciSPEC with LED stabilization. Gamma unit with GM tube for high dose rate situations and He-3 tube for neutron detection.
identiFINDER S900 DU 403.3-NG Ruggized housing for harsh environmental deployments. Consists of an NaI(Tl) scintillation detector with K40 for calibration verification and a DSP based electronic with LED stabilization. Wired gamma unit only with 2" x 3" NaI detector and a GM tube for high dose rate situations in a weatherproof PVC housing.
identiFINDER S900 DU 203.2-NG Encapsulated system suitable for installations on walls, inside door jams, behind counters, and the like. It consists of an 2" x 3" NaI(Tl) scintillation detector with K40 for calibration verification and a DSP based dsciSPEC with LED stabilization. Gamma unit with GM tube for high dose rate situations.

identiFINDER S900 Fixed Radiation Detector

There are no reviews yet.


Related Items
Pen Radiation Dosimeter from S.E. International
Pen Radiation Dosimeter

S.E. International


$165.00
Radiation Alert Pen Dosimeter Charger from S.E. International

$290.00
Monitor 4EC from S.E. International
Monitor 4EC

S.E. International


$475.00
Radiation Alert Monitor 4 Monitor 4
Radiation Alert Monitor 4

S.E. International


$445.00