Single Point Bump Test & Calibration Station for GX-2009
RKI’s SDM-2009 calibration station for the GX-2009 is available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2009 inside the SDM-2009 calibration module, the GX-2009’s display will indicate whether it’s transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.
Multi Module System
The SDM-2009 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends. Network up to 10 SDM-2009 stations to charge, calibrate, and bump test 10 instruments simultaneously.
Configurations:
P/N
|
Contents
|
81-SDM2009-01
|
Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing & installation CD
|
81-SDM2009-02
|
Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator
|
81-SDM2009-03
|
Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 58AL cyl H2S (25 ppm)/CO/CH4/O2
|
81-SDM2009-06
|
Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl H2S (25 ppm)/CO/CH4/O2
|
Single Point Bump Test & Calibration Station for GX-2009
Input Power
|
12 VDC NOTE: AC Adapter with 100 – 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard.
|
Environmental Conditions
|
- For Indoor Use Only
- -10° C to 40° C, below 80% Relative Humidity, Non-Condensing
|
Applicable Instruments
|
GX-2009
|
Max Records Saved
|
200 (stand-alone). Unlimited with software
|
Number of Cal Cylinders
|
1 Calibration gas, 1 fresh air and 1 exhaust
|
Standard Accessories
|
- AC Adapter
- USB Flash Drive
- Single Module Data Viewer Software
- SDM GX Docking Station PC Controller Program
- Inlet Air Filter
- Instruction Manual
- 10 Foot Long Exhaust Tube
- One 3 Foot Long Tube for GAS Fitting
- 2 T-Fittings (for PC Controlled Configuration only)
- 10 Foot Long 3/16 Inch Tube for GAS manifold-
ing (used for PC Controlled Configuration only)
- Check Valve (used for PC Controlled
Configuration only)
- USB Cable, Type A to Type B
|
Single Point Bump Test & Calibration Station for GX-2009
There are no reviews yet.